Diagnostic Error Code
FRU/Action
170-195-XXX
Voltage Sensor(s) Test aborted by user
1.
Information
2.
Re-start the test, if necessary
170-196-XXX
Voltage Sensor(s) test halt, error threshold
exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
170-197-XXX
Voltage Sensor(s) test warning
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
170-198-XXX
Voltage Sensor(s) test aborted
1.
If a component is called out, make sure
it is connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″Undetermined problems″
section
170-199-XXX
Voltage Sensor(s) test failed, cause unknown
1.
Go to the
Undetermined problems
section
2.
Flash the system and re-test
3.
Replace component under function test
170-250-XXX
170-251-XXX
Voltage Sensor(s) Voltage limit error
1.
Power supply
2.
System board
170-254-XXX
Voltage Sensor(s) Voltage Regulator Module
error
1.
Voltage Regulator Module (VRM)
2.
Microprocessor
3.
System board
175-000-XXX
Thermal Sensor(s) Test Passed
1.
No action
175-0XX-XXX
Thermal Sensor(s) failure
1.
Flash system
2.
System board
175-195-XXX
Thermal Sensor(s) Test aborted by user
1.
Information
2.
Re-start the test, if necessary
175-196-XXX
Thermal Sensor(s) test halt, error threshold
exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
175-197-XXX
Thermal Sensor(s) test warning
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
175-198-XXX
Thermal Sensor(s) test aborted
1.
If a component is called out, make sure
it is connected and/or enabled
2.
Flash the system and re-test
3.
Go to
″Undetermined problems″ section
Chapter 6. Symptom-to-FRU Index