ROUBLESHOOTING
Verifying ATM OC-3
Switchover
If the Redundant ATM OC-3 card does not become active upon failure 
of the primary ATM OC-3, use the following command to verify that 
the PHY Automatic Failover parameter is Enabled:
CB5000>  show module <slot.phy>
 
verbose
If the PHY_Automatic_Failover parameter is not Enabled, use the 
following command to enable it:
CB5000>  set module <slot>.1 phy_automatic_failover enable
If the ATM Backbone SwitchModule is still experiencing problems after 
you complete the procedures above, refer to Obtaining Technical 
Assistance later in this chapter.
Resetting the ATM 
Backbone 
SwitchModule
You can reset the ATM Backbone SwitchModule by either pressing the 
front panel Reset button or issuing the DMM Reset command.
CAUTION: If you reset the ATM Backbone SwitchModule using the 
DMM RESET command, the module does not lose saved setup 
information. However, performing a reset may cause some of the data 
being transmitted at that moment to be lost and statistic counters to 
be reset to zero.
Using the Reset
Button
Each ATM Backbone SwitchModule front panel houses a Reset button. 
The Reset button resets the ATM Backbone SwitchModule and executes 
power up self-test diagnostics. 
CAUTION: Use the Reset button only if you suspect a problem with the 
ATM Backbone SwitchModule. Using the Reset button to reset an ATM 
Backbone SwitchModule disrupts network traffic.
To ensure that you do not lose any configuration information, before 
you use the Reset button:
Save any configuration changes