Promise Technology M310p User Manual

Page of 262
VTrak M310p, M210p Product Manual
102
Manual Rebuild
If a physical drive has failed, identify and replace the drive, then rebuild the disk 
array as described below:
1.
Click the Subsystem 
 icon in Tree View. 
2.
Click on the Disk Arrays 
 icon. 
3.
Click on the Disk Array 
 icon. 
If there are multiple disk arrays, choose the icon with the yellow !. 
4.
Click on the Background Activities tab in Management View. 
5.
Click the dropdown menu on the Background Activity tab and select Start 
Rebuild
6.
Select the Source physical drive.
This is a remaining functional physical drive in the disk array. 
7.
Select the Target physical drive.
This is the replacement physical drive. 
8.
Click the Submit button. 
The Disk Array Background Activity tab will show the rebuild on the replacement 
(target) physical drive. Depending on the size of the physical disk involved, this 
process will take some time.
To view more information, click on the Rebuild on PDx link.
Disk Array Background Activity
The Disk Array–Background Activity tab provides information about functions that 
run in the background on your subsystem:
Disk array Migration 
Disk array Rebuild 
Predictive Data Migration (PDM) 
Spare drive Transition 
Start Background Function
To start a background function: 
1.
Click the Subsystem 
 icon in Tree View. 
2.
Click on the Disk Arrays 
 icon. 
3.
Click on the Disk Array 
 icon. 
4.
Click the Background Activities tab in Management view.