VTrak M310p, M210p Product Manual
122
When you first power-up the VTrak, it beeps twice to show normal operation.
The audible alarm sounds at other times to inform you that the VTrak needs 
attention. But the alarm does not specify the condition. When the alarm sounds:
Check the front and back of VTrak for red or amber LEDs, as described 
above.
If email notification is enabled, check for new messages.
Check the different functions in the CLU for component problems.
Check the event log (see page 154).
When a continuous tone sounds, there are multiple alarm patterns sounding at 
the same time. 
To make alarm settings, see “Buzzer” on page 166.
CLU Connection
There are two connections methods for the CLU:
Serial – Requires a null modem cable (included with VTrak) to connect the 
serial ports on the Host PC and VTrak 
Telnet – Requires a network connection between the Host PC and VTrak’s 
Management Port.
Serial Connection
Before you begin, be sure the null modem cable is connected between the Host 
PC and VTrak, and that both machines are booted and running.
1.
Start your PC’s terminal emulation program. 
2.
Press Enter once to launch the CLU. 
Telnet Connection
If your Telnet connection has not been setup, refer to “Set Up Serial Cable 
Connections” on page 14.
To start the telnet program:
1.
Go to the command line prompt (Windows) or click the terminal icon (Linux), 
then run:
telnet 192.168.1.56 2300
The IP address above is only an example. Use your VTrak's Management 
port IP address. 2300 is the Telnet port for the VTrak. 
The telnet login screen appears.