Promise Technology M310p User Manual

Page of 262
VTrak M310p, M210p Product Manual
166
4.
Press Y to continue.
The screen will go blank.
5.
Wait for two to three minutes.
6.
Re-establish your Telnet connection to the VTrak CLU.
If you cannot re-establish a connection, wait 30 seconds, then try again.
Restart over Serial
To restart the VTrak subsystem on a serial connection:
1.
From the Main Menu, highlight Additional Info and Management and press 
Enter.
2.
Highlight Shutdown or Restart and press Enter
3.
Press the spacebar to display Restart then press Enter.
A warning message appears.
4.
Press Y to continue.
The screen will display shutdown and startup functions.
5.
When the 
Login:
 prompt appears, log into the CLU again.
Buzzer
This function enables the buzzer on the controller. VTrak’s audible alarm sounds 
a 10-second continuous beep to indicate that one or more logical drives is offline.
To change buzzer settings:
1.
From the Main Menu, highlight Buzzer and press Enter.
A list of Controllers appears with the current buzzer setting and status.
2.
Highlight the Controller whose buzzer you want to set and press Enter.
3.
Highlight Enabled and press the spacebar to toggle between Yes and No.
4.
Press Ctrl-A to save your settings.