Promise Technology M310p User Manual

Page of 262
VTrak M310p, M210p Product Manual
172
Replace Cooling Unit Blower
The blower (scroll fan) in each cooling unit is replaced as an individual part. No 
tools are required for this procedure. 
To replace a blower:
1.
Verify that the Fan LED is amber or red (above).
2.
Press the release button and pull the handle downward as shown above.
3.
Pull the cooling unit out of the VTrak enclosure. An example of a VTrak 
cooling unit appears below.
4.
Loosen the thumbscrew (above, left). A retainer keeps the thumbscrew in 
place. 
Fan LED
Loosen the thumbscrews
Lift the top section