Promise Technology M310p User Manual

Page of 262
VTrak M310p, M210p Product Manual
194
Capacity Coercion also affects a replacement drive used in a disk array. 
Normally, when an physical drive fails, the replacement drive must be the same 
capacity or larger. However, the Capacity Coercion feature permits the 
installation of a replacement drive that is slightly smaller (within 1 gigabyte) than 
the remaining working drive. For example, the remaining working drives can be 
80.5GB and the replacement drive can be 80.3, since all are rounded down to 
80GB. This permits the smaller drive to be used. 
Without Capacity Coercion, the controller will not permit the use of a replacement 
physical drive that is slightly smaller than the remaining working drive(s).
Initialization
Initialization is done to logical drives after they are created from a disk array. 
Initialization sets all data bits in the logical drive to zero. The action is useful 
because there may be residual data on the logical drives left behind from earlier 
configurations. For this reason, Initialization is recommended for all new logical 
Hot Spare Drive(s)
A hot spare is a disk drive that is connected to the disk array system but is not 
assigned as a member of the disk array. In the event of the failure of a drive 
within a functioning fault tolerant disk array, the hot spare is activated as a 
member of the disk array to replace a drive that has failed. 
VTrak will replace a failing disk drive in a disk array with an unassigned drive, if 
one is available. The unassigned drive is not part of any disk array. Such a drive 
is called a hot spare drive. There are two types:
Global – An unassigned disk drive available to any disk array on the VTrak.
Dedicated – An unassigned disk drive that can only be used by a specified 
disk array.
The hot spare policy function lets you select whether a disk array will access any 
unassigned disk drive or a designated drive in the event of disk drive failure. See 
“Spare Drive” on page 114 (WebPAM PROe) or “Spare Drive Management” on 
page 155 (C
LU) for information on how to make this setting.
Caution
When you initialize a logical drive, all the data on the logical drive 
will be lost. Backup any important data before you initialize a 
logical drive.