Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-111
ANN-PT (Announcement Port) 
10
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. This error type indicates that the circuit pack has been removed or has 
been insane for more than 11 minutes. To clear the error, reinsert or 
replace the circuit pack.
b. This error is logged and the port is alarmed when an alarm is raised on the 
Announcement circuit pack because of a faulty condition with a common 
circuit pack resource. Any one of the following alarmed errors on the 
Announcement circuit pack causes this error to be logged against the 
Announcement Port: 1793, 2049, 2305, 2561. Follow the ANN-BD 
(Announcement Circuit Pack) Maintenance documentation to resolve 
these alarms. When the corresponding circuit pack alarm is cleared, this 
alarm clears.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
Announcement Port Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1
Playback Speech Memory 
Array (PSMA) Test (#206)
MINOR
ON
test port PCSSpp sh r 3
18
0
The port was busied out
WARNING
OFF
release port PCSSpp
130 (a)
None
WARNING
ON
test port PCSSpp sh
257
Channel Administration 
Memory Array (CAMA) 
Test (#205)
MINOR
ON
test port PCSSpp l r 3
17667
In-line error
513
140AY Channel Sanity 
Inquiry Test (#222)
MINOR
ON
test port PCSSpp sh r 3
17684
In-line error
769 (b)
None