DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-182
BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port) 
10
Layer 1 Transmission Error Counter Test (#624)
This test reads and clears the BRI port’s Layer 1 Transmission error counter 
maintained on the BRI-LINE circuit pack. This counter is incremented by the 
circuit pack when it detects a Layer 1 transmission problem. The test passes if 
the value of the counter is 0 (that is, the error is cleared). If the counter is not 
zero, the test fails, and the value of the counter is displayed in the Error Code 
field.
This error is most likely due to a problem with the wiring or the endpoint or 
adjunct (verify that the wiring meets the configuration rules defined in 
DEFINITY 
Communications System Generic 1 and Generic 3i Wiring
, 555-204-111). It does 
1
FAIL
The BRI-LINE circuit pack reports that it has detected an 
overcurrent condition and has turned off the EPF.
1. As necessary, check and repair the wiring between 
the circuit pack and the endpoint or adjunct. Check 
the endpoints and replace one or both sets if the 
sets are drawing too much current. Execute the 
test 
port PCSSpp
 command and review the results of 
the EPF Inquiry Test to verify the repair. If this test is 
still failing, proceed to Step 2.
2. Execute the 
test port PCSSpp
 command, and 
review the results of the Level 1 Status Inquiry Test. 
If this test is also failing, then follow the repair 
procedure for the Level 1 Status Inquiry Test. 
Otherwise, escalate this problem to the next tier.
PASS
The Electronic Power Feed Inquiry Test reports that the 
EPF is on.
2000
ABORT
Response to the test was not received from the circuit 
pack within the allowable time period.
1. If the test aborts repeatedly a maximum of five times, 
reset the circuit pack via the 
busyout board PCSS
 
and 
reset board PCSS
 commands.
2. If the test aborts again, replace the circuit pack.
2012
ABORT
Internal System Error.
Table 10-59.
TEST #622 Electronic Power Feed Inquiry  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page