Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-199
BRI-SET, ASAI-ADJ, BRI-DAT 
10
System Technician-Demanded Tests: 
Descriptions and Error Codes
When inspecting errors in the system and deciding which ones to address, 
always investigate errors associated with the circuit pack and port first. Clearing 
these error codes first may also clear errors generated against the endpoint. 
When all circuit pack and port errors have been cleared, and errors still exist 
against the endpoint, always investigate errors in the order they are presented in 
58
Bearer 
Capability Not 
Presently 
Available
Requested bearer capability is implemented, but 
not administered. No B-channel administered. See 
recommendation 50 above.
SERVICE OR 
OPTION NOT 
IMPLEMENTED
65
Bearer Service 
Not 
Implemented
Requested service not implemented in switch or 
endpoint.
69
Requested 
Facility Not 
Implemented
Requested service not supported in switch or 
endpoint.
1. Consult switch and endpoint documentation to 
determine service support.
2. If Step 1 does not resolve the problem, escalate 
to the next tier.
ADJUNCT/SWI
TCH ERROR 
CONDITIONS
81
Invalid CRV
An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency between 
the switch and the adjunct. See the CallVisor 
protocol reference manual.
2. If step 1 does not resolve the problem, escalate 
to the next tier.
Table 10-65.
ISDN-BRI Cause Values  — 
Continued
Code
Explanation
Recommendation
Continued on next page