Routine Maintenance Procedures
Page 5-26
Software Upgrade
5
3. Select
Reset System
from the
Maintenance
menu.
4. Select
Restart System
from the
Reset System
menu.
Save Upgraded Translations onto New
Translation Card
Translation Card
1. Enter
status system 1
, and press
Enter
to verify the system is in “active”
mode.
2. If the system contains a TN750/B Announcement circuit pack, check for
completion of an automatic restore of announcements before removing
the original translation card. If the system has been running for at least 45
minutes since power on, this operation should be complete. Check the
yellow LED on the TN750/B which is lit during the download. If the restore
did not start within 15 minutes of power on, enter
the original translation card. If the system has been running for at least 45
minutes since power on, this operation should be complete. Check the
yellow LED on the TN750/B which is lit during the download. If the restore
did not start within 15 minutes of power on, enter
restore
announcements
, and press
Enter
.
3. At this point, all telephones should be working properly.
4. Insert the new Release 5.4 translation card. Verify the write switch is down.
5. The original translation card can be reformatted and reused. Enter
format
card-mem announcements
and press
Enter
. This formats the original
translation card into Release 5.4 format (even if no announcement circuit
packs are installed).
packs are installed).
6. Enter
save translation
, and press
Enter
. This instructs the system to write
all translation information from memory onto the translation card.
7. If the system is equipped with a TN750/B Announcement circuit pack and
announcements were restored in the above step, enter
save
announcements [‘from’ cabinet(1-X). carrier (A-D), slot (0-20)]
and
press
Enter
. Where cabinet/carrier/slot is the location of the TN750/B.
NOTE:
If multiple TN750/B circuit packs are present, you
must
specify the
slot location for the save announcements command. If there is only
one announcement circuit pack, the system defaults to the proper
location.
one announcement circuit pack, the system defaults to the proper
location.
Enable TTI
If TTI was optioned prior to the software upgrade:
1. Enter
change system-parameters features
and press
Enter
.
2. Use page 2 of the form to change the TTI field back to
y
.
Enable Scheduled Maintenance
Enter
change system-parameters maintenance
, and press
Enter
. Enable the
scheduled daily maintenance.