Lucent Technologies R5SI User Manual
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-330
CO-TRK (CO Trunk)
10
3. PBX On-Hook first (Drop Message): Open the Tip-Ring Loop, no loop
current
a. CO Response: Open circuit on Tip
4. CO On-Hook first (Disconnect): Open circuit on Tip, no loop current
Hardware Error Log Entries and Test to Clear
Values
Values
Table 10-92.
CO Trunk Error Log Entries
Error
Type
Type
Aux Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
57347
None
15 (b)
any
Port Audit Update
Test (#36)
Test (#36)
18
0
busyout trunk
<grp>/<mbr>
<grp>/<mbr>
WARNING
OFF
release trunk
<grp>/<mbr>
<grp>/<mbr>
130(c)
None
WARNING
ON
test trunk <grp>/<mbr>
257 (a)
50176
None
513 (a)
57364
None
MAJ/MIN/
WRN
WRN
2
ON
769 (a)
57392
None
MAJ/MIN/
WRN
WRN
2
OFF
1025 (e)
Any
Demand
Diagnostic Test
(#3)
Diagnostic Test
(#3)
MAJ/MIN/
WRN
WRN
2
OFF
test port PCSS sh r 2
1281 (e)
Any
Demand
Diagnostic Test
(#3)
Diagnostic Test
(#3)
MAJ/MIN/
WRN
WRN
2
ON
test port PCSS sh r 3
1537
Dial Tone Test (#0)
MAJ/MIN/
WRN
WRN
2
OFF
test port PCSS l r 2
1793
Loop Around and
Conference Test
(#33)
Conference Test
(#33)
MAJ/MIN/
WRN
WRN
2
ON
test port PCSS l r 3
2049
NPE Cross Talk
Test (#6)
Test (#6)
MAJ/MIN/
WRN
WRN
2
ON
test port PCSS l r 3
Continued on next page