Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-354
CO-TRK (CO Trunk) 
10
Transmission Test (#844-848)
This test is non-destructive.
NOTE:
Tests #844-848 are not supported on a International switch.
These tests are run by the Automatic Transmission Measurement System 
(ATMS). They are not part of the long or short trunk test sequences. Instead, they 
are run on demand with the 
test analog-testcall
 command or as part of ATMS 
scheduled testing.
PASS
This test passed. Translation information was 
successfully updated on the circuit pack. User-reported 
troubles on this port should be investigated by using 
other port tests and by examining trunk or external 
wiring. If the trunk is busied out, the test does not run, 
but returns PASS. To verify that the trunk is in-service:
1. Enter 
status-command
 to verify that the trunk is 
in-service. If the trunk is in-service, no further action 
is necessary. If the trunk is out-of-service, continue 
to Step 2.
2. Enter 
release-trunk
 command to put trunk back into 
in-service.
3. Retry the test command.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board).
1. Check to ensure that the board translations are 
correct. Translate the board, if necessary.
2. Issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board
 command. This should 
re-establish the linkage between the internal ID and 
the port.
Table 10-98.
TEST #36 Port Audit Update Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page