Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-375
CUST-ALM (Customer-Provided Alarming Device) 
10
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests: 
Descriptions and Error Codes
There are no errors associated with the CPAD CUST-ALM MO. The 
test 
customer-alarm PC
 command is provided to allow a technician to check that the 
customer-provided alarming device is correctly installed and functional. It is 
recommended that this test be run at least once after both the switch and the 
customer alarm have been installed.
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
Customer-Provided Alarming Device Test
, for example, you may also clear errors 
generated from other tests in the testing sequence.
Customer-Provided Alarming Device Test (#115)
This test closes the relay that activates the CPAD for 1 minute only within the port 
network specified. If it takes longer than 1 minute to check that the CPAD has 
been activated, the Repeat field on the 
test customer-alarm PC
 command can 
be used to close the relay for up to 99 minutes. Note that when the repeat option 
is used, the results for Test #115 come back immediately and, for each test that 
passed, the CPAD is kept on for that many minutes. The CPAD does not go off 
after 1 minute and then come back on. Instead, the CPAD is kept on continuously 
for the entire time. If the CPAD is being activated and deactivated in a flickering 
fashion, there is a problem with either the CPAD, or the Maintenance/Tape 
Processor, or the EPN Maintenance circuit pack.
1.
D = Destructive; ND = Nondestructive
Table 10-101.
Customer Provided Alarming Device Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
none
none
none
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Customer-Provided Alarming Device Test (#115)
X
X
ND