Lucent Technologies R5SI User Manual
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-375
CUST-ALM (Customer-Provided Alarming Device)
10
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests:
Descriptions and Error Codes
Descriptions and Error Codes
There are no errors associated with the CPAD CUST-ALM MO. The
test
customer-alarm PC
command is provided to allow a technician to check that the
customer-provided alarming device is correctly installed and functional. It is
recommended that this test be run at least once after both the switch and the
customer alarm have been installed.
recommended that this test be run at least once after both the switch and the
customer alarm have been installed.
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
inspecting errors in the system. By clearing error codes associated with the
Customer-Provided Alarming Device Test
, for example, you may also clear errors
generated from other tests in the testing sequence.
Customer-Provided Alarming Device Test (#115)
This test closes the relay that activates the CPAD for 1 minute only within the port
network specified. If it takes longer than 1 minute to check that the CPAD has
been activated, the Repeat field on the
network specified. If it takes longer than 1 minute to check that the CPAD has
been activated, the Repeat field on the
test customer-alarm PC
command can
be used to close the relay for up to 99 minutes. Note that when the repeat option
is used, the results for Test #115 come back immediately and, for each test that
passed, the CPAD is kept on for that many minutes. The CPAD does not go off
after 1 minute and then come back on. Instead, the CPAD is kept on continuously
for the entire time. If the CPAD is being activated and deactivated in a flickering
fashion, there is a problem with either the CPAD, or the Maintenance/Tape
Processor, or the EPN Maintenance circuit pack.
is used, the results for Test #115 come back immediately and, for each test that
passed, the CPAD is kept on for that many minutes. The CPAD does not go off
after 1 minute and then come back on. Instead, the CPAD is kept on continuously
for the entire time. If the CPAD is being activated and deactivated in a flickering
fashion, there is a problem with either the CPAD, or the Maintenance/Tape
Processor, or the EPN Maintenance circuit pack.
1.
D = Destructive; ND = Nondestructive
Table 10-101.
Customer Provided Alarming Device Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
none
none
none
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
Customer-Provided Alarming Device Test (#115)
X
X
ND