DATA-BD maintenance.
NPE Audit Test (#50)
The system sends a message to the on-board microprocessor to update the 
network connectivity information for all the NPEs on the circuit pack.
Control Channel Loop Around Test (#52)
This test queries the circuit pack for its circuit pack code and vintage and verifies 
its records.
Table 10-104.
TEST #50 NPE Audit Test 
Error 
Code
Test 
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1019
ABORT
Test already in progress.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
The circuit pack’s NPEs have been updated with their translation.
Continued on next page
Table 10-105.
TEST #52 Control Channel Loop Around Test 
Error 
Code
Test 
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
Communication with this circuit pack is successful.