Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-393
DATA-CHL (Network Control Data Channel) 
10
This test prevents any control stimuli from being received from or sent to the TDM 
Bus control channel preventing the establishment of new connections over the 
DATA-CHLs. However, existing connections are not (and cannot) be dropped.
Data Channel Remote Maintenance Loop Around 
Test (#109)
This test verifies the integrity of the entire DATA-CHL (that is, the software, dual 
port RAM, and hardware that compose it). It verifies that a connection can be 
established over the DATA-CHL and that the DATA-CHL can correctly send and 
receive data over the connection (that is, over the TDM Bus). The test actually 
involves two DATA-CHLs: the DATA-CHL that is the target of the test and a 
second, arbitrary, unbusy DATA-CHL. A connection is set up by placing a call 
out from the arbitrary DATA-CHL and into the target DATA-CHL. Data is looped 
over the connection in each direction (that is, the target DATA-CHL is tested as 
both a sender of data and a receiver of data). The test checks that the data 
received by one DATA-CHL is the same as the data that was sent by the other 
DATA-CHL.
Because it establishes a connection between two Network Control Data 
Channels (DATA-CHLs) across the TDM Bus, this test does more than just verify 
the integrity of the target DATA-CHL. It also verifies the integrity of the 
DATA-CON (by establishing the connection) and of the TDM Bus and 
Tone-Clock circuit pack (by sending and receiving data).
Table 10-109.
TEST #108 Data Channel Dual Port RAM Test 
Error 
Code
Test 
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2020
ABORT
Refer to “STBY-SPE” for a description of these error codes.
FAIL
The DATA-CON dual port RAM is not functioning correctly. Either the 
software cannot correctly read from it and/or write to it or the hardware 
cannot correctly read from it and/or write to it. Connections cannot be 
established over the DATA-CHLs.
1. Execute the command again.
2. If the problem persists, replace the TN777 Network Control circuit 
pack. After the Network Control circuit pack has been replaced, its 
Time-of-Day clock must be set using the 
set time
 command.
PASS
The DATA-CON dual port RAM is functioning. Connections can be 
established over the DATA-CHLs.
Continued on next page