Routine Maintenance Procedures 
Page 5-40
System Features 
5
NOTE:
The following test call descriptions are for voice terminal users:
Trunk Test Call
The trunk test call accesses specific Tie or CO trunks. DID trunks cannot be 
accessed.
To place a call:
1. Dial the Facility Test Call Feature Access Code (for example, 197, see 
Note), and listen for dial tone.
NOTE:
The Facility Test Call Access Code (FAC) is administered on the 
Feature Access Codes Form. The 197 FAC code used here is an 
example. For more information on FAC, refer to 
DEFINITY 
Communications System Generic 3 Implementation
, 555-230-653.
2. Dial the 6-digit port number "PCSSpp"
The channels on a DS1 trunk are addressed by using the channel number 
for the port number.
3. Listen for one of the following tones:
Dial Tone or Silence—trunk is connected. Go to Step 4. If you hear 
a dial tone, it is coming from the far end. If the far end has been 
disabled, you do not hear dial tone. However, depending on 
far-end administration, you may still be able to dial digits. All digits 
dialed after the port number are transmitted using end-to-end 
DTMF signaling; therefore, if the trunk being tested is a rotary trunk, 
it is not possible to break dial tone.
Reorder Tone—trunk is busy or maintenance busy.
Intercept Tone— a trunk or touch-tone (DTMF) receiver has not 
been accessed.
4. Place a call. Even if you do not hear a dial tone, you may still be able to 
dial digits, depending on the administration of the far-end switch.
All digits dialed after the port number are transmitted using end-to-end 
DTMF signaling; therefore, if the trunk being tested is a rotary trunk, it will 
not be possible to break dial tone.
P
=
Port network number (1 for PPN or 2 or 3 for EPN)
C
=
Carrier number (A=1, B=2, C=3, D=4, E=5)
SS
=
Slot number (01—20)
pp
=
Port number