Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-413
DATA-CON (Network Control Driver) 
10
Error Log Entries and Test to Clear Values
Note:
a. As previously described, the DATA-CON is not directly accessible via a 
system technician command so there is no Test to Clear value that can be 
used to directly clear errors and alarms raised against the DATA-CON. 
However, since the DATA-CON and the DATA-CHLs share the same set of 
tests (that is, test the same set of hardware, firmware, and software), 
DATA-CON errors and alarms are accompanied by DATA-CHL errors and 
alarms.
Therefore, the strategy to clear DATA-CON errors and alarms is to first clear all 
DATA-CHL errors and alarms. After DATA-CHL errors and alarms have been 
cleared, allow about 60 minutes for maintenance software to run internally and to 
automatically clear the DATA-CON errors and alarms.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Because the DATA-CON uses the same set of tests as the DATA-CHLs, refer to 
the "System Technician-Demanded Tests: Descriptions and Error Codes" in the 
DATA-CHL (Network Control Data Channel) Maintenance documentation for a 
description of the tests and their associated error codes.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
Table 10-113.
Network Control Driver Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear 
Value 
(a)
0
1
0
Any
Any
Any
none
1
Local Loop Back Test (#111)
MINOR
ON
none
257
Any
Remote Maintenance Loop Around 
Test (#109)
MINOR
ON
none
513
Crosstalk Test (#110)
MINOR
ON
none
769
Any
Dual Port RAM Test (#108)
MINOR
ON
none