DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-440
DID-DS1 (DS1 DID Trunk) 
10
Port Audit and Update Test (#36)
This test sends port level translation data from the switch processor to the DS1 
Interface circuit pack to assure that the trunk’s translation is correct. Translation 
updates include the following data: trunk type (in/out), dial type, timing 
parameters, and signaling bits enabled. The port audit operation verifies the 
consistency of the current state of the trunk as kept in the DS1 Interface circuit 
pack and in the switch software.
PASS
The port can correctly conference multiple connections. 
User-reported troubles on this port should be investigated using 
other port tests and by examining station, trunk, or external 
wiring.
NOTE:
This test always passes for TN712 Analog circuit packs 
prior to Vintage 14 and for TN742 prior to Vintage 4.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). 
This could be due to incorrect translations, no board is inserted, 
an incorrect board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use 
the 
lIst config
 command and resolve any problems that are 
found.
2. If the board was found to be correctly inserted in step 1, 
issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board long
 command. This should re-establish 
the linkage between the internal ID and the port. If this is not 
the case, check to see that there is a valid board inserted.
Table 10-122.
TEST #7 Conference Circuit Test  — 
Continued
Error
Code
Test 
Result
Description/ Recommendation
Continued on next page