Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-482
DIG-LINE (Digital Line) 
10
Digital Line NPE Crosstalk Test (#9)
One or more Network Processing Elements (NPEs) reside on each circuit pack 
with a TDM Bus interface. The NPE controls port connectivity and gain, and 
provides conferencing functions on a per-port basis. The NPE Crosstalk Test 
verifies that this port’s NPE channel talks on the selected time slot and never 
crosses over to time slots reserved for other connections. If the NPE is not 
working correctly, one-way and noisy connections may be observed. This test is 
part of a port’s Long Test Sequence and takes about 20 to 30 seconds to 
1015
ABORT
The system will not allow this test to be run because the 
station is/has not been busied out. Busy out the station 
with the /E3busyout station/E1 command. 
16
FAIL
The secondary channel (data Information Channel 2 or 
I2 is not operating properly. User impact may range 
from noticing nothing to not being able to use this 
terminal. Check the results of "Voice and Control 
Channel Local Loop Test (#13). If that test fails, suspect 
the Digital Line circuit pack. If that test passes then 
replace the terminal. If both test fail, and component 
replacement does not change the results, then:
1. Run circuit pack tests to check the tone generator 
circuit pack and the Tone Detector circuit pack 
using the 
test board 
UUCSS s command.
2. Resolve any problems that are detected on the Tone 
Generator circuit pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit pack 
are functioning properly, and the tests still fail, 
escalate the problem.
PASS
Voice and Control Channel Local Loop test passed. All 
channels are transmitting properly.
1. To be sure that this is not an intermittent problem, 
repeat this test up to a maximum of ten times to 
make sure it continues to pass.
2. If complaints persist (noisy connections for voice. 
corrupted data transfer for data), examine the 
station, connections, and wiring.
Table 10-129.
TEST #1201 Digital Terminal Remote 
Loop Around Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page