Lucent Technologies R5SI User Manual
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-538
DS1-BD (DS1 Interface Circuit Pack)
10
NPE Connection Audit Test (#50):
The system sends a message to the on-board microprocessor to update the
network connectivity translation for all the Network Processing Elements (NPEs)
on the circuit pack.
network connectivity translation for all the Network Processing Elements (NPEs)
on the circuit pack.
1.
D = Destructive, ND = Non-destructive
CSU Equipment Loopback Test
(#1210)
(#1210)
X
D
CSU Repeater Loopback Test
(#1211)
(#1211)
X
D
CPE Loopback Jack Test (#1212)
X
D
Far CSU Loopback Test (#1213)
X
D
One-Way Span Test (#1214)
X
D
Inject Single Bit Error (#1215)
X
D
End Loopback/Span Test (#1216)
X
D
Table 10-146.
TEST #50 NPE Connection Audit Test
Error
Code
Code
Test Result
Description/ Recommendation
None
2100
2100
ABORT
System resources required for this test are not available.
1019
ABORT
Test already in progress.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
The circuit pack’s NPEs have been updated with their translation.
Continued on next page
Table 10-145.
System Technician-Demanded Tests: DS1-BD —
Continued
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset
Board
Sequence
test
ds1-loop
Command
D/ND
1
Continued on next page