Maintenance Object Repair Procedures 
Page 10-562
DS1-BD (DS1 Interface Circuit Pack) 
10
Minor Alarm Inquiry Test (#143)
The Minor alarm raised by a DS1 Interface circuit pack indicates that the average 
bit error rate on the DS1 facility is greater than 1/1,000,000, but less than 1/1000. 
The Minor Alarm Inquiry Test is used to determine that the received DS1 bit error 
rate is greater than 1/1,000,000 and less than 1/1000. When D4 framing mode is 
selected, the DS1 Interface circuit pack takes 41 minutes to recognize and report 
a Minor alarm and 41 minutes to recognize and report that a Minor alarm 
condition is cleared. If ESF framing mode is selected, the DS1 Interface circuit 
pack takes 10 minutes to recognize and report a Minor alarm and 10 minutes to 
recognize and report that a Minor alarm condition is cleared.
When the DS1 Interface circuit pack detects a Minor alarm condition, it will send 
a MINOR-ALARM message to the maintenance software. After the maintenance 
software receives a MINOR-ALARM message, the Minor Alarm Inquiry Test is 
initiated to confirm the Minor alarm. All trunks on the circuit pack are kept in the 
in-service state after the Minor alarm is confirmed. The Minor Alarm Inquiry Test 
is run every 10 minutes until the Minor alarm is cleared.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). 
This could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
add ds1 
PCSS
 command to administer the DS1 interface if it is not already 
administered.
2. If board was already administered correctly, check the error log to 
determine if the board is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the 
busyout 
board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the link between the internal ID and the port.
Table 10-154.
TEST #142 Major Alarm Inquiry Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page