Maintenance Object Repair Procedures 
Page 10-594
DS1-BD (DS1 Interface Circuit Pack) 
10
End Loopback/Span Test (#1216)
This test is destructive.
The End Loopback/Span Test will terminate an active loopback or span test on a 
TN767E DS1 circuit pack. Bit error counting against the received test pattern 
stream is terminated and sending of the framed 3-in-24 test pattern is halted. If 
either the CPE Loopback Jack or the far-end CSU is looped, the appropriate 
loopback deactivate code is sent. If the loopback could not be deactivated, then 
the test will FAIL and a MINOR alarm will be noted in the alarm log until the 
loopback is cleared.
The test is highly destructive and can only be initiated by a system technician 
demanded 
test ds1-loop PCSS end-loopback/span-test
 command. Since only 
one of these three different long-duration loopback/span tests can be active at a 
time, the TN767E circuit pack knows which loopback/span test to terminate.
All trunks or ports on the DS1 Interface circuit pack must be busied out via the 
system technician 
busyout board
 command before running this End 
Loopback/Span Test.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). 
This could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
add ds1 
PCSS
 command to administer the DS1 interface if it is not already 
administered.
2. If board was already administered correctly, check the error log to 
determine if the board is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the link between the internal ID and the port.
Table 10-165.
TEST #1215 Inject Single Bit Error Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page