DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Routine Maintenance Procedures 
Page 5-59
System Features 
5
An ISDN-PRI test call can be originated via either the 
synchronous
 or the 
asynchronous
 method. Each method is described below.
Synchronous Method
One command is used in this method to start, stop and query an ISDN-PRI test 
call. In the synchronous method, an outgoing ISDN-PRI test call may be part of a 
system technician-demanded long test sequence to test a circuit pack, port, or 
trunk. Therefore, the command line entry can be any of the following:
test trunk <grp>/<mbr> long [repeat #]
test port PCSSpp long [repeat #]
test board PCSS long [repeat #]
The "long" qualifier must be entered in the above commands in order for the ISDN 
test call to run. The repeat number (#) can be any number from 1 through 99 
(default = 1).
The following information is displayed in response to the above commands:
Port
: The port address (PCSSpp) is the port network number, carrier 
designation, slot, and circuit of the maintenance object under test.
Maintenance Name
: The type of maintenance object tested.
Test Number
: The actual test that was run.
Test Results
: Indicates whether the test passes, fails, or aborts.
Error Code
: Additional information about the results of the test. (See the 
ISDN Trunk Maintenance documentation for details.)
Asynchronous Method 
NOTE:
The asynchronous method requires a Maintenance/Test circuit pack to be 
physically present in the system.
In this method, four commands are used to start, stop, query, and list an 
outgoing ISDN-PRI test call. These commands are as follows:
clear isdn-testcall <grp>/<mbr>
 (stop)
list isdn-testcall
 (list)
status isdn-testcall <grp>/<mbr>
 (query)
test isdn-testcall <grp>/<mbr> [minutes]
 (start)
NOTE:
Before placing an outgoing ISDN-PRI test call, verify that the FAC on the 
System Features Form has been administered as well as the Far End Test 
Line No and TestCall Bearer Capability Class (BCC) on the Trunk Group 
Administration Form. Furthermore, if the ISDN-PRI trunk is of the "cbc" (call