Page 10-621
DUPINT (Duplication Interface Circuit Pack) 
10
done entirely on the Duplication Interface circuit pack. The test passes if the data 
sent matches the data received. This test does not check the physical serial 
channel that is printed on the backplane or carried by the ICC.
Duplication Interface Circuit Pack Status Query 
Test (#315)
This test is used to detect the presence of Duplication Interface circuit packs A 
and B. To determine the status of Duplication Interface circuit pack B, a query is 
sent to the Duplication Interface circuit pack A. To determine the status of 
Duplication Interface circuit pack A, a query is sent to the Maintenance/Tape 
Processor on the active carrier. The response to either query indicates the status 
of the handshake to the appropriate Duplication Interface circuit pack.
Table 10-178.
TEST #280 Inter-Duplication Interface Circuit Pack Loop Back Test 
Error 
Code
Test 
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
2000
ABORT
Response to the test request was not received within the allowable time 
period.
2033
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
The tested UART on the Duplication Interface circuit pack is defective.
1. Replace the Duplication Interface circuit pack.
2. Rerun the test.
NO 
BOARD
The Duplication Interface circuit pack B has failed to reply to handshaking 
either from Duplication Interface circuit pack A.
1. Refer to NO BOARD description for the Duplication Interface Circuit 
Pack Status Query Test (#315).
PASS
The Inter-DUPINT UART on the tested Duplication Interface circuit pack is 
good.
Continued on next page