DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-629
E-DIG-STA (Emulated Digital Line) 
10
h. Internal system error; no action is necessary. The error counters 1, 2, 3, 4, 
5, 6, 10, 11, 12, 13, 14, 15, and 16 do not have any significance for this 
MO.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
Voice and Control Channel Local Loop Around Test, for example, you may also 
clear errors generated from other tests in the testing sequence.
Digital Line NPE Crosstalk Test (#9)
One or more Network Processing Elements (NPEs) reside on each circuit pack 
with a TDM Bus interface. The NPE controls port connectivity and gain and 
provides conferencing functions on a per-port basis. The NPE Crosstalk Test 
verifies that this port’s NPE channel talks on the selected time slot and never 
crosses over to time slots reserved for other connections. If the NPE is not 
working correctly, one-way and noisy connections may be observed. This test is 
part of a port’s Long Test Sequence and takes about 20 to 30 seconds to 
complete. Crosstalk testing occurs on both the primary information channel 
(voice) and the secondary information channel (data) associated with each 
digital station port. If this test fails on either channel, the station and the DTDM 
are taken out-of-service.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Voice and Control Channel Local Loop Around Test (#13)
X
D
NPE Crosstalk Test (#9)
X
ND
Station Lamp Updates Test (#16)
X
ND