Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-768
INADS (INADS Link) 
10
10
INADS (INADS Link)
The INADS Link MO represents the software and communications link required 
by the switch to make a call to the Initialization and Administration System 
(INADS). The purpose of the INADS Link MO is to check the communications link 
between the DEFINITY Generic 1 and INADS and verify that the alarm notification 
process works correctly. An INADS technician can test the process remotely to 
verify that alarms are reported to INADS, or a system technician may want to test 
the connection while on-site at installation time or during subsequent service 
calls.
Although the INADS Link MO is never alarmed, the errors are logged. The errors 
are only logged as a result of the 
test inads-link
 command being issued.
Error Log Entries and Test to Clear Values
The Hardware Error Log entries are described as part of the INADS Link Test 
description. 
Short and Long Test Sequences
The 
test inads-link
 command is different from other test commands. This 
command does not have a long or short option, and the test on the INADS Link 
does not have an associated test number. When the command is different from 
other test commands. This command does not have a long or short option, and 
the test on the INADS Link does not have an associated test number. When the 
test inads-link
 command is issued, the user immediately sees either the 
"Command successfully completed" or "Command failed" message command is 
issued, the user immediately sees either the "Command successfully completed" 
or "Command failed" message.
INADS Link Test (no test number)
The INADS Link Test attempts to place a call to INADS (in the background) to 
verify the communications link to INADS. When the 
test inads-link
 command is 
entered, the user immediately sees either "Command successfully completed" or 
"Command failed." The "Command failed" message appears when a previously 
run command is entered, the user immediately sees either "Command 
successfully completed" or "Command failed" The "Command failed" message 
appears when a previously run 
test inads-link
 command is in progress or the 
system has active alarms which must be reported to INADS. The "Command 
successfully completed" means the switch will start the attempt to call INADS in 
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command 
to Run
Full Name of MO
INADS
none
test inads-link
INADS Link