Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-834
ISDN-TRK (DS1 ISDN Trunk) 
10
Service State Audit (#256)
These trunks may be in one of several service states. This test performs a Service 
State Audit with the far-end switch. 
For interfaces using country protocol 1 (including US), the Service State Audit 
executes in all trunk service states. A message is sent to the far-end switch to 
ensure that both sides agree on the service state. A PASS for this test simply 
means that the message has been successfully sent. Two minutes are allowed 
for a reply. If no reply is received within that 2 minute window, the message is 
sent out again. If that attempt fails, an error is logged (Error Type 3073) and the 
switch then attempts another Service State Audit every 15 minutes. If the trunk 
was initially INS (in-service), it is then placed in the MTC/FE (maintenance state, 
far-end problem) state. No outgoing calls are placed over this trunk, but 
incoming calls are accepted. If an incoming call is presented while in such a 
state, a Service State Audit attempt is immediately attempted (that is, the switch 
does not wait for the 15-minute cycle, but tries to recover immediately). 
For interfaces not using country protocol 1, the Service State Audit executes only 
if the trunk is in the OOF/FE state. A message is sent to the far-end switch to 
1018
ABORT
Maintenance is disable on this trunk.
1. Enable maintenance by entering ‘‘y’’ in the ‘‘Maintenance Tests?’’ field 
on page 2 of the 
change trunk-group
 form.
1114
ABORT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals a maximum of 5 times.
4
FAIL
There is a problem with the Signaling Channel.
1. If the Packet Control circuit pack is used consult the procedures for 
the ISDN-PRI Signaling Group (ISDN-SGR). Further information may 
also be obtained by consulting the procedures for the ISDN-PRI 
Signaling Channel (ISDN-PLK).
2. If the Processor Interface is used consult the procedures for 
Processor Interface Link (PI-LINK).
8
FAIL
There is a problem with the DS1 interface circuit pack.
1. Consult the procedures for DS1 interface circuit pack 
(DS1-BD/UDS1-BD).
PASS
The signaling link hardware is OK.
Table 10-234.
TEST #255 Signaling Link State Check Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page