Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-908
MODEM-PT (Modem Pool Port) 
10
MODEM-PT (Modem Pool Port)
The Modem Pool Port provides an interface for digital and analog data 
communication devices or ports connected to the PBX. It may be thought of as a 
PBX data communications "conversion resource" because it converts analog 
modem signals typically used in the telephone network into digital signals that 
are compatible with the internal PBX network and vice versa.
There may be a number of these conversion resources available in the PBX, 
each assigned to one of five available Modem Pool Groups. Only one conversion 
resource is used per data connection. The PBX software usually adds the 
conversion resource into a data connection if it determines that it is necessary for 
the call. Typical connections that include Modem Pool conversion resources 
include data calls from Analog Line or Central Office Trunk ports to any digital 
port or Digital Line or Trunk ports to any analog port. An example of a Data 
Module to Central Office Trunk connection using a Modem Pool conversion 
resource is shown in 
. When a local data call originates from an 
analog port normally used for voice service only and terminates on a digital port, 
a Data Origination access code must be dialed before the extension number for 
the Modem Pool conversion resource to be included in the connection.
Refer to 
 while reading the following paragraph.
Each Modem Pool conversion resource contains two ports. One of these, an 
Analog Line Port, is connected (via the PBX network) to the Analog Line or 
Central Office Trunk Port that is the source of the modem signal. The second port 
is referred to as the digital port and is connected (again through the PBX 
network) to the Digital Line or Trunk port associated with the Data Module in the 
connection. The analog modem signals enter the analog port of the conversion 
resource in standard Pulse Code Modulation (PCM) format but are converted into 
Data Communications Protocol (DCP) format before going to the Digital Line or 
trunk in the connection.
There are two primary types of Modem Pool conversion resources available: an 
Integrated Pooled Modem and a Combined Modem Pool. The integrated TN758 
Pooled Modem circuit pack contains two independent 300 or 1200 baud 
conversion resources. Each conversion resource contains two interfaces to the 
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier 
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier 
where the circuit pack is located (for example, 01, 02, ..., etc.); and pp is the 2-digit 
port number (for example, 01).
MO Name As 
It Appears in 
Alarm Log
Alarm 
Level
Initial System 
Technician 
Command to Run
1
Full Name of MO
MODEM-PT
MINOR
test port PCSSpp sh
Modem Pool Port