MODEM-PT (Modem Pool Port) 
10
Modem Pool Conference Test (#97)
This test is destructive.
This test checks most of the switching and gain control functions provided by the 
NPE circuit in the analog section of the conversion resource. This test 
conferences a 1004-Hz tone through the NPE, looping it back so that it can be 
verified with a Tone Detector circuit.
NONE
FAIL
The test failed. This error is internal to the Pooled 
Modem circuit pack and does not involve external 
equipment or interfaces.
1. Busyout both of the TN758 Pooled Modem 
conversion resources on the circuit pack containing 
the failing conversion resource.
2. If the test continues to fail, replace the Pooled 
Modem circuit pack and retest.
3. If the circuit pack fails after replacement, escalate 
the problem.
ANY
FAIL
The NPE of the tested port was found to be transmitting 
in error. This condition causes noisy and unreliable 
connections.
1. If the remaining ports are currently not in use (that is, 
yellow LED is off), attempt to reset the circuit pack. 
Then repeat the test.
2. If the test fails again, replace the circuit pack.
PASS
The port is correctly using its allocated time slots. 
User-reported troubles on this port should be 
investigated using other port tests and by examining 
station, trunk, or external wiring.