Maintenance Object Repair Procedures 
Page 10-963
M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386] 
10
M/T-DIG (Maintenance/Test Digital
Port) [G3iV1-1.286, G3iV2-386]
The Maintenance/Test Digital Port is a port on the TN771D (or later vintage) 
Maintenance/Test circuit pack, which is required for G3iV1.1-286 or G3iV2-386. 
Ports 2 and 3 are Digital Ports. The Maintenance/Test Digital Port provides the 
ability to perform digital (that is, ISDN-PRI) trunk testing via the TDM Bus. For an 
ISDN-PRI test call, connections are set up in the system as shown in 
When the Maintenance/Test Digital Port is participating in an ISDN-PRI test call, 
the port sends a stream of pseudo-random data along the connected B-channel. 
The far end loops back this data, and the Maintenance/Test Digital Port 
compares the data to that which was sent. Errors are recorded on a bit and block 
basis. Refer to ISDN-TRK (DS1ISDN Trunk) Maintenance documentation for more 
information on ISDN-PRI test calls.
The Maintenance/Test Digital Port maintenance ensures that the digital trunk 
testing function is operating correctly. The Maintenance/Test Digital Port is 
alarmed if maintenance determines that the digital port is operating incorrectly.
NOTE:
An alarm on the Maintenance/Test Digital Port reduces service, but does 
not block it since the ISDN-TRK has other means to determine the health of 
the ISDN-PRI trunk facility. However, to accurately measure the error 
performance and to ensure accuracy of the health of the ISDN-PRI trunk, 
the Maintenance/Test circuit pack should be replaced when a new circuit 
pack is available.
1.
Where P is the port network number (1 for PPN, 2 or, 3 for EPN-1 and 3 for EPN-2); C is the 
carrier designation (A, B, C, D, or E); SS is the address of the slot in the carrier where the circuit 
pack is located (01, 02, ..., etc.); and pp is the 2-digit port number (for example, 01).
MO Name As 
It Appears in 
Alarm Log
Alarm 
Level
Initial System 
Technician Command 
to Run
1
Full Name of MO
M/T-DIG
Minor
test port PCSSpp l 
Maintenance/Test Digital Port
M/T-DIG
Warning
release port PCSSpp 
Maintenance/Test Digital Port