Maintenance Object Repair Procedures 
Page 10-969
M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386] 
10
Digital Port Loop Around Test (#13)
This test is a modification of the Voice and Control Channel Local Loop Test used 
by Digital Station (DIG-LINE) maintenance. This test does not perform the control 
channel and secondary information channel loop around tests as described for 
DIG-LINE, as these data paths do not exist for the Maintenance/Test Digital Port. 
The primary information channel is tested by first looping back the data channel 
onto the TDM Bus, and then sending a digital count from the Tone-Clock circuit 
pack and receiving the same digital count with a general purpose tone detector. 
A conference test is done next for the primary information channel. This test is the 
same as Conference Test #6.
Only one value (Pass, Fail, or Abort) is generated as a result of the two tests. If 
either fails or aborts, the sequence is stopped.
Any
FAIL
The NPE of the tested port was found to be transmitting 
in error. This causes noisy and unreliable connections.
1. If the remaining ports are currently not in use (yellow 
LED is off), try to reset the circuit pack. Then repeat 
the test.
2. If the test fails again, replace the circuit pack.
PASS
The port is correctly using its allocated time slots. 
User-reported troubles on this port should be 
investigated using other port tests and by examining 
station, trunk, or external wiring.
Table 10-278.
TEST #9 NPE Cross Talk Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page