Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Reliability Systems: A Maintenance Aid 
Page 6-20
Repair Procedures for High and Critical Reliability 
6
Software Running
If system software is running, determine which SPE is the Standby SPE by 
issuing the 
status system
 command from the G3MT terminal. Look at the SPE 
and MODE fields in the upper left corner of the form to determine which SPE (A or 
B) is the Active SPE; it is labeled as ”active.” The other SPE is the Standby SPE 
and is labeled as either “standby,” “maint,” or “down.”
Follow the “Circuit Pack Replacement Procedure” described later 
for each 
Standby SPE circuit pack to be replaced. 
Continue with this procedure as follows.
1. If alarms are against the Active SHDW-CIR, Active DUPINT, or 
SHDW-LNK, replace the Duplication Interface circuit pack. Proceed to the 
 sections as applicable.
2. If these sections do not need to be referenced, proceed to the 
 section.
The rest of this section describes how the system behaves when there are faulty 
circuit packs in the SPEs and is meant to be informative rather than part of the 
general procedure of replacing SPE circuit packs.
NOTE:
When circuit packs 
other than the Duplication Interface circuit pack in 
the Active SPE
 are defective, the SPE containing the more severely 
defective circuit packs is usually in the Standby SPE. 
Handling SHDW-CIR and SHDW-LNK Alarms 
in the Active SPE
Check for the existence of SHDW-CIR alarms against the Active SPE Duplication 
Interface circuit pack or SHDW-LNK alarms. If there are Active SPE SHDW-CIR or 
SHDW-LNK alarms, inform the customer that a COLD 2 restart of the system is 
needed and determine a time at which to restart may be. At that time, complete 
the following steps:
1. Make sure that the tape (memory card) in the Active SPE tape unit 
(memory card slot) has the most current translations. If it does not, issue 
the 
save translations spe-active
 command to put the most current 
translations on it.
2. Exchange the tapes (memory cards) in the Active SPE and Standby SPE 
so that the Standby SPE tape unit (memory card slot) contains the tape 
(memory card) from the previous step.
3. For a 386 system, if the Standby SPE is not in standby mode, issue the 
refresh spe-standby
 command to put it into standby mode if possible 
(see the previous Note). If the Standby SPE was successfully put into 
standby mode, then issue the 
reset system interchange
 command to