Maintenance Object Repair Procedures 
Page 10-1059
PI-LINK (Processor Interface Link) 
10
When the data module fails to respond to the EIA interface (query 
request) the AUX_Data is set to 41. This may indicate problems 
with the data module or connection to the data module. Other 
errors specific to the data module may also be logged if this is the 
case.
j. TN765 PI-BD determined that the ISDN link went down. Check 
connectivity with the other end. Busyout and then release the link to 
recover. Occurs if DS1 maintenance detected a problem or the remote 
end is busied out or is down. This also occurs if the ISDN link is unstable 
or if there is excessive noise on the line. See the "Link Recovery" section.
k. Excessive LAPD (link-access procedure on the D-channel) invalid frame 
errors. Could be a noisy line or problems with the TN765 Processor 
Interface circuit pack. Also check DS1-BD Maintenance documentation. 
See the "Link Recovery" section.
l. Occurs 90 seconds after a 2817 Error Code if link does not recover. At this 
time, all ISDN trunks associated with this link are put into a maintenance 
far-end state (see ISDN-TRK for details). See the "Link Recovery" section.
m. The application level process associated with the link has failed to 
establish a data connection with the far end. This problem prevents data 
from being processed. The condition may exist even if the link is in a data 
transfer state. Busyout, and release the link to restart it. This is not a 
Processor Interface hardware problem.
Aux values of concern; any others can be ignored.
n. Excessive (over threshold) HDLC transmit or receive error rates were 
reported. Aux Data is the HDLC error rate reported. See the Link Recovery 
section for troubleshooting this problem
Link Recovery
This section describes the general procedure to take to recover from link errors 
and alarms. Refer to the "Troubleshooting ISDN-PRI Problems" section in 
, before proceeding with this "Link 
Recovery" strategy.
1. Determine the link status using the 
status link
 command. If the link status 
is "in-service" and (for X.25 links) all the pairs of processor channels are 
complete under "LOCAL/REMOTE PROCESSOR CHANNELS" (that is, 
every "/" is followed by a processor channel number, not a blank), then the 
link is operating correctly and no further action should be taken. If the link 
433
OCM application did not start correctly. Reboot the 
OCM adjunct.
435
Application level process could not connect to session 
layer process.