Maintenance Object Repair Procedures 
Page 10-1063
PI-LINK (Processor Interface Link) 
10
TDM Loop Around Test (#183)
This test is destructive.
This test requires that you enter the 
busyout link lnk-no
 command before 
running the test. This means that the DCS, AUDIX, or ISDN link, for example, are 
torn down. This test checks the health of the TN754 or TN784 DIG-LINE or the 
TN722 or TN767 DS1 Interface circuit pack. This depends on which circuit pack 
is used on the link. The TN754 or TN784 Digital Line or DS1 Interface circuit pack 
is put into loop around mode while the PI-BD is instructed to go into remote loop 
around. If this test fails, and the previous Test #182 passes, then the TN754 or 
TN784 Digital Line or the DS1 Interface circuit pack should be replaced. It is not 
run on ports administered as EIA.
12
FAIL
PI-BD reported that Loop Around Test failed.
1. Retry the test.
2. If it continues to fail, try resetting the circuit pack by the 
test interface 
PCS long
 command. This TEARS down all other links on this circuit 
pack (DCS, AUDIX, ISDN, etc.).
3. If the problem still exists, replace the TN765 circuit pack.
PASS
The on-board Loop Around Test on the TN765 circuit pack passed. Most of 
the hardware on the circuit pack was tested except for the TDM Bus 
buffers. If problem is isolated to TN765 and this test passes, then replace 
TN765 circuit pack since TDM Bus buffers could be at fault.
13
ABORT
The TN765 circuit pack has not been reset yet or is currently being reset.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If test continues to abort with error code 13, then check status of all 
BX.25 and/or ISDN-PRI links on this TN765 via the 
status link lnk-no
 
command. If all links are not in-service, then reset the TN765 using the 
test interface PCS long
 command.
3. If the TN765 fails to reset, refer to the PI-SCI section of this manual.
4. Retry the 
test link lnk-no
 command.
5. If the test still aborts with error code 13 or from step 2, and some links 
are in-service and an error code is still present, escalate the problem.
Table 10-305.
TEST #182 Processor Interface Loop Around Test  — 
Continued
Error 
Code
Test 
Result
Description/Recommendation 
Continued on next page