Maintenance Object Repair Procedures
Page 10-1079
PI-SCI (System Communication Interface)
10
SCI SELF TEST Test (#231)
This is an on-board test which checks the basic functionality of the TN765 circuit
pack. This test runs in the background periodically, or it can be invoked via the
pack. This test runs in the background periodically, or it can be invoked via the
test interface PCS
command. If this test continuously fails, then replace the
TN765 Processor Interface circuit pack. Refer to
pack.
200
FAIL
Checksum of Processor Interface failed.
1. Wait 1 minute and retry.
2. If the test continues to fail with a checksum failure, there could be
corruption on the tape. Replace the tape with a new tape that contains
Processor Interface firmware. Retry the command. For G3i-386 and
later, see note (b) of Hardware Error Table for repair procedure.
Processor Interface firmware. Retry the command. For G3i-386 and
later, see note (b) of Hardware Error Table for repair procedure.
3. In G3i-286 if the problem continues to exist after replacing the tape,
then replace the TN765 Processor Interface circuit pack. Refer to
for instructions
about replacing an SPE complex circuit pack. Retry the command.
23
199
9000s
199
9000s
FAIL
Processor Interface Download failed. Refer to TABLE A Tape Unit Aux Data
Table and follow the repair recommendations.
Table and follow the repair recommendations.
1. Wait one minute and retry. See note (b) of Hardware Error Table for
repair procedure
2. If problem persists and TAPE is idle when command is entered, then a
problem may exist in either the TAPE or the Processor Interface circuit
pack. Replace the tape with a new tape that contains Processor
Interface firmware. Retry the command.
pack. Replace the tape with a new tape that contains Processor
Interface firmware. Retry the command.
PASS
TN765 Processor Interface circuit pack initialized correctly. Processor
Interface links (BX.25 and ISDN) should recover now. See PI-LINK for more
information if links do not recover.
Interface links (BX.25 and ISDN) should recover now. See PI-LINK for more
information if links do not recover.
Table 10-314.
TEST #176 SCI Start Test —
Continued
Error
Code
Code
Test
Result
Description/ Recommendation
Continued on next page