Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1090
PKT-BUS (Packet Bus) 
10
Packet Circuit Pack Audit Test (#573)
This test determines whether Packet circuit packs have reported Packet 
Bus-related in-line errors within the last minute. If so, the failure code indicates 
whether one or more circuit packs have reported failures within the last minute.
Due to the one minute time constraint included as part of this test, the test is 
designed to delay 15 seconds before returning a result in cases where the test 
has failed within the last five minutes. This procedure helps ensure that a 
repeated sequence of the test does not always yield the same result. If no failure 
has occurred in the last five minutes, a PASS is returned immediately.
1xxx
The Maintenance/Test Packet Bus port has reconfigured the Packet Bus 
around the faulty leads. This occurs only in high or critical reliability systems.
2xxx
The Maintenance/Test Packet Bus port is unable to correct all of the Packet 
Bus faults it has detected.
x0xx
None of the Packet Bus faults are open faults.
x1xx
At least some of the Packet Bus faults are open faults. Look for Error Type 
2305 in the Error Log. The Aux Data value indicates the number of open 
leads.
xxZZ
The last 2 digits of the error code indicate the total number of faulty Packet 
Bus leads detected by the Maintenance/Test Packet Bus port.
1. Refer to the "Packet Bus Fault Isolation Flowchart" section in Chapter 9 to 
determine the cause of the failures.
PASS
No faults have been detected on the Packet Bus by the Maintenance/Test 
circuit pack. This indicates that the Packet Bus is operating correctly.
Table 10-319.
Test #573 Packet Circuit Pack Audit Test 
Error 
Code
Test 
Result
Description/ Recommendation
2500
ABORT
An internal operation failed; the test could not be completed.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 10-318.
TEST #572 Maintenance/Test Circuit Pack Query Test
 — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page