Maintenance Object Repair Procedures 
Page 10-1094
PKT-CTRL (Packet Control Circuit Pack) 
10
The 
status packet-control C
 command provides useful information about the 
Packet Control circuit pack. This command displays the service state of the 
circuit pack and various link-related information. The service state "out" indicates 
that service is not being provided and users are being disrupted. Maintenance 
takes the Packet Control circuit pack out-of-service due to certain faults, or as a 
result of the 
busyout packet-control C
 command being run. Refer to the "Status 
Commands" section in 
 for more information on the 
status packet-control
 
command.
Error Log Entries and Test to Clear Values
Notes:
a. This error occurs when maintenance software resets the Packet Control 
circuit pack due to an in-line error or certain test failures. Once a threshold 
number of these errors occur, maintenance places the Packet Control 
circuit pack into an out-of-service state, and a major on-board alarm is 
raised on the Packet Control circuit pack.
b. This error occurs due to certain in-line errors and test failures. This error is 
very serious, and when it occurs maintenance software immediately 
escalates testing to the destructive reset test (#586).
Table 10-320.
Packet Control Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
1(a)
Any
None
MAJOR
ON
reset packet-control C (k)
18
0
busyout 
packet-control C
WARNING
OFF
release packet-control C
257 (b)
Any
None
MAJOR
ON
reset packet-control C (k)
513 (c)
0
None
769 (d)
Any
Loop Around Test 
(#585)
1025 (e)
1
Parity Circuitry Test 
(#584)
MINOR
ON
test packet-control C l
1281 (f)
0
None
1537 (g)
0
None
1793 (h)
0
None
2049 (i)
0
None
2305 (j)
Any
Download Test 
(#581)
MAJOR
OFF
reset packet-control C