DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1102
PKT-CTRL (Packet Control Circuit Pack) 
10
Packet Control Reset Test (#586)
This test resets the Packet Control circuit pack, downloads Packet Control circuit 
pack firmware form tape, and then causes the Packet Control circuit pack to 
begin operation.
!
WARNING:
This test is destructive and disrupts service when run on the Packet Control 
circuit pack in the Active SPE. This test is not destructive when run on the 
Packet Control circuit pack in the Standby SPE of a High or Critical 
Reliability system. When this test is run on the Packet Control circuit pack 
on the Active SPE, the "busyout packet-control C" command must be 
executed first. Once testing has been completed, a busied-out Packet 
Control should be released via the release packet-control C command.
1-3
FAIL
Maintenance was unable to establish a loop around link from the Packet 
Control circuit pack back to itself, or was unable to receive the data that was 
sent out over one side of the loop around link.
1. Issue 
test packet-control C short
 command to retry the test.
2. If the same error code is observed, maintenance software automatically 
escalates the testing. No specific action is required.
PASS
The Packet Control circuit pack can send and receive data correctly.
Table 10-325.
TEST #585 Packet Control Loop Around Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page