Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1134
POWER (Battery & Battery Charger for DC-Powered Systems 
10
POWER (Battery & Battery Charger 
for DC-Powered Systems
NOTE:
For environment maintenance, the PPN or EPN cabinet configuration 
aspects for a High or Critical Reliability system are irrelevant.
The environment maintenance strategy to be used depends on both the cabinet 
configuration and the type of powering. Refer to the DC-POWER (DC Power) 
Maintenance documentation for environment maintenance strategy.
In a DC-powered cabinet, the POWER MO still exists, but serves no functional 
purpose. Because the system cannot determine the type of powering provided, 
all POWER tests should always pass or abort. Since the tests should never fail, 
POWER alarms should not be raised.
Error Log Entries and Test to Clear Values
1.
Where P is an appropriate port network number determined via the Port field from the Alarm 
or Error Log.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to 
Run
1
Full Name of MO
POWER
MINOR
test environment P 
Battery & Battery Charger
Table 10-333.
Power Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off
 Board
Test to Clear Value
0
1
0
Any
Any
Any
test environment P sh r 1
1
Any
Battery & Battery Charger 
Query Test (#5) (Error Code 8)
MINOR
ON
test environment P sh r 1
257
Any
Battery & Battery Charger 
Query Test (#5) (Error Code 4)
MINOR
ON
test environment P sh r 1
Continued on next page