Lucent Technologies R5SI User Manual
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1322
SW-CTL (Switch Control)
10
Switch Control Destructive EPN Maintenance
Board Interface Test (#325)
Board Interface Test (#325)
This test is destructive.
This test writes test patterns into the EPN Maintenance circuit pack interface and
verifies that it can read back these test patterns successfully. Messages to or
from the EPN Maintenance circuit pack can be lost when this test is run.
verifies that it can read back these test patterns successfully. Messages to or
from the EPN Maintenance circuit pack can be lost when this test is run.
any
FAIL
This failure indicates that communications with the Maintenance circuit
pack in the EPN is probably not possible. The EPN Manager I may not be
usable.
pack in the EPN is probably not possible. The EPN Manager I may not be
usable.
1. Run the Short Test Sequence several times to make sure the error is
occurring consistently, run the Long Test Sequence to reset the Switch
Control. Sometimes running the Long Test Sequence may clear the
problem. Remember the Long Test Sequence is
Control. Sometimes running the Long Test Sequence may clear the
problem. Remember the Long Test Sequence is
destructive
. Placing
and receiving calls is affected for several seconds.
2. Replace the Netcon circuit pack whenever it is convenient for the
customer (unduplicated system) or right away (High or Critical
Reliability system).
Reliability system).
3. The procedure for replacing the Netcon circuit pack is described in
. The procedure
for doing the same in systems without High or Critical Reliability is
described in
described in
PASS
The EPN Maintenance circuit pack interface between the processor and
the Switch Control is working correctly. Test #325 is a more thorough test of
this interface but it is
the Switch Control is working correctly. Test #325 is a more thorough test of
this interface but it is
destructive
.
Table 10-401.
TEST #325 Switch Control Destructive EPN
Maintenance Board Interface Test
Error
Code
Code
Test
Result
Description/ Recommendation
1005
ABORT
The system does not contain an EPN so this test is not executed.
32500
ABORT
Test disabled via software patch.
Continued on next page
Table 10-400.
TEST #324 Switch Control EPN Maintenance Board Interface Test —
Continued
Error
Code
Code
Test
Result
Description/ Recommendation
Continued on next page