Maintenance Object Repair Procedures 
Page 10-1356
TAPE (Tape Unit) [G3iV1.1-286] 
10
Tape Reset Test (#67)
This test resets the tape portion of the Processor on the Maintenance/Tape 
Processor (PR-MAINT), and it resets the shared RAM on the Processor circuit 
pack (TN770). The test can pass when no drive is present because it never 
accesses the tape drive.
Table 10-409.
TEST #66 Tape Diagnostic Test 
Error 
Code
Test 
Result
Description/ Recommendation
1029 to 
2051
ABORT
Refer to the STBY-SPE (Standby SPE) Maintenance 
documentation for a description of these error codes.
9000’s
ABORT 
or FAIL
Refer to Table A in 
 and follow the recommended repair strategy for 
specific Aux Data.
Any 
Others
ABORT 
or FAIL
Refer to Table B in 
 and follow the recommended repair strategy for 
specific Aux Data.
PASS
This is a comprehensive test of the Tape Unit. The test 
verifies that the tape drive is in good working order.
Continued on next page
Table 10-410.
TEST #67 Tape Reset Test 
Error 
Code
Test 
Result
Description/ Recommendation
1029 to 
2051
ABORT
Refer to the STBY-SPE (Standby SPE) Maintenance 
documentation for a description of these error codes.
9000’s
FAIL
Refer to Table A in 
 and follow the recommended repair strategy for 
specific Aux Data.
Any 
Others
FAIL
Refer to Table B in 
 and follow the recommended repair strategy for 
specific Aux Data.
PASS
Communication with the tape processor is possible at a 
very basic level.
Continued on next page