Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-14
busyout journal-printer 
8
Permissions
The following default logins may execute this command: system technician, 
inads, init, nms.
Examples
busyout journal-printer pms-log 
busyout journal-printer wakeup-log
Description
The busyout journal-printer command will put the maintenance object associated 
with a specified pms-log or wakeup-log link in a maintenance busy state. There 
will be no periodic or scheduled tests performed on the busied out maintenance 
object until it is released. Also, no activity will occur over the links (i.e. no data will 
be transferred to the printer) and the link will be dropped. Warning alarms are 
generated (error type 18) on each maintenance object busied out, so that INADS 
can access the state of the objects. The release journal-printer command will 
return the object to operation.
A link is comprised of several components. It involves a far end data module, a 
simulated data channel on a PKTINT board, a manager that initiates and 
maintains the link, and a controller/protocol that services the link. A 
controller/protocol is usually a transient process that exists for as long as the link 
is up. A link is considered up if a physical connection is established. A link can 
be considered to be up while no useful work can be performed over it, in this 
case the link is insane and should be torn down. These links provide 
asynchronous data connections from the switch to peripherals.
For general information on journal printer links, see the second paragraph in the 
Description section of the 
 manual pages.
For information on what a journal printer is and does, see the second paragraph 
in the Description section of the "status journal-link" manual pages.
Defaults
None.