DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1408
TDM-BUS (TDM Bus) 
10
Set the number of slips to trigger 
loss of signal
 - currently 30 per 5 
millisecond period
Enable the on-board synchronization switching algorithm (see above)
Enable holdover operation (TN2182 only).
This is not a test and will always pass without identifying or reporting any 
Tone-Clock circuit pack errors.
TDM-Clock Circuit Pack Type Test (#574)
The purpose of this query is to check if the required type of Tone-Clock circuit 
pack (TN780) is present when the Stratum 3 clock is administered.
Table 10-427.
TEST #151 TDM Bus Clock Parameter Update Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT 
Internal system error
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
The Tone-Clock circuit pack parameters have been successfully updated.
Continued on next page
Table 10-428.
TEST #574 TDM Clock Circuit Pack Type Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
The system could not allocate the necessary resources for the test.
1. Wait 1 minute and retry the test.
FAIL
The Tone-Clock circuit pack in the system is not a TN780. The Stratum 3 
clock requires a TN780 Tone-Clock circuit pack.
1. Replace the Tone-Clock circuit pack with a TN780. The old circuit pack 
may still be good, and need not be discarded.
PASS
The required TN780 circuit pack is present.
Continued on next page