Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1411
TDM-CLK (TDM Bus Clock) 
10
See 
 for more details of the escalation plan. 
There 
exists a strong interdependency among the DS1 Interface circuit pack 
Maintenance, Synchronization Maintenance, and TDM Bus Clock Maintenance 
MOs
.
See the section on “TONE-BD” for a discussion of the relationship of Tone-Clock 
circuit packs with the various Reliability Options.
Error Log Entries and Test to Clear Values
Tone-Clock 
Role
Synchronization 
Facilities
Initial External 
Synchronization 
Source
Backup External 
Synchronization 
Source
Internal 
Source
MASTER
Stratum 3 Clock
Source "A"
Source "B"
Local 
oscillator
DS1 Primary and 
Secondary
DS1 Primary
DS1 Secondary
DS1 Primary Only
DS1 Primary
None
No External Source
None
None
SLAVE
PNC Duplication
Active EI
Standby EI
No PNC 
Duplication
Active EI
None
Table 10-430.
TDM Bus Clock Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
1
Test to Clear Value
0
2
0
Any
Any
Any
test tone-clock UUC sh r 1
1(a)
0
None
MINOR
OFF
18(b)
0
busyout tone-clock 
UUC
WARNING
OFF
release tone-clock UUC
130(c)
None
257(d)
None
WARNING
OFF
513(e)
Any
Clock Circuit Status 
Inquiry (#148)
MINOR
3
OFF
test tone-clock UUC 
769(f)
Any
Clock Circuit Status 
Inquiry (#148)
MAJOR‡
ON
test tone-clock UUC sh r 10
1025(g)
Any
Clock Slip 
Inquiry(#149)
test tone-clock UUC sh
Continued on next page