Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1426
TIE-DS1 (DS1 Tie Trunk) 
10
Hardware Error Log Entries and Test to Clear 
Values
DS1 Tie Trunk Maintenance Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test trunk 
<grp>/<mbr> sh r 1>
1 (a)
57476
57477
57485
57487
15 (b)
Any
Port Audit and 
Update Test (#36)
18 (c)
0
busyout trunk 
<grp>/<mbr>
WARNING
OFF
release trunk 
<grp>/<mbr>
130 (d)
None
WARNING
ON
test trunk 
<grp>/<mbr>
257 (e)
57473
57474
513(f)
57392
DS1 Tie Trunk 
Seizure Test (#136)
MIN/MAJ
2
769(g)
57393
DS1 Tie Trunk 
Seizure Test (#136)
MIN/MAJ
1025
DS1 Tie Trunk 
Seizure (Test #136)
MAJ/MIN/ 
WRN
3
OFF
test trunk 
<grp>/<mbr> r 2
1281
Conference Circuit 
(Test #7)
MAJ/MIN/ 
WRN
ON
test trunk 
<grp>/<mbr> l r 4
1537
NPE Crosstalk 
Test (#6)
MAJ/MIN/ 
WRN
ON
test trunk 
<grp>/<mbr> l r 3
1793 (h)
test board PCSS long
2305(i)
50944
DS1 Tie Trunk 
Seizure Test (#136)
MIN/MAJ
OFF
Continued on next page