Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1451
TIE-TRK (Tie Trunk) 
10
testing configuration allows for the connection of Tie Trunks back-to-back in the 
same switch to verify the operation of Tie Trunk ports. The tests can be 
performed in either the E&M or simplex modes. For details, refer to the "Analog 
Tie Trunk Back-to-Back Testing" section in 
Hardware Error Log Entries and Test to Clear 
Values
Table 10-441.
TIE Trunk Error Log Entries 
Error 
Type
Aux Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp s r 1
1 (a)
2
16384
None
1 (b)
57476
None
1 (c)
57477
None
1 (d)
3
57483
None
1 (e)
57485
None
15 (f)
Any
Port Audit Update 
(#36); Audit and 
Update (#36) 
18 (g)
0
busyout trunk 
<grp/mbr>
WARNING
OFF
release trunk 
<grp/mbr>
130 (h)
None
WARNING
4
ON
test trunk 
<grp>/<mbr>
257 (i)
57473
None
WARNING
OFF
257 (j)
57474
None
WARNING
OFF
257 (k)
57475
None
WARNING
OFF
513
Any
EPF M and E Lead 
(#74)
MAJ/MIN/ 
WRN
test port PCSSpp sh r 
3
769
57481
EPF M and E Lead 
(#74)
MAJ/MIN/ 
WRN
ON
test port PCSSpp sh r 
3
1025 (l)
Any
 
57392
5
None
MAJ/MIN/ 
WRN
 
MINOR
OFF
Continued on next page