Lucent Technologies R5SI User Manual

Page of 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1490
TONE-BD (Tone-Clock Circuit Pack) 
10
Hardware Error Log Entries and Test to Clear 
Values
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the 
set 
options
 command.
Tone-Clock Circuit Pack Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off
 Board
Test to Clear Value
0
1
0
Any
Any
Any
test tone-clock PC sh
1(a)
0
Circuit pack 
removed or SAKI 
Sanity Test (#53)
MINOR
ON
18(b)
0
busyout tone-clock 
PC
WARNING
OFF
release tone-clock PC
23(c)
0
None
WARNING
OFF
125(d)
None
MINOR
ON
126(e)
None
MINOR
ON
257
65535
Control Channel 
Test (#52)
MINOR
ON
test tone-clock PC r 20
257(f)
Any
None
513(g)
Any
None
769(h)
4358
None
1025(i)
4363
NPE Audit Test (50)
test tone-clock PC sh
1538(j)
Any
None
MINOR
ON
2049(k)
0
Clock Health Inquiry 
Test (#46)
MAJOR
ON
set tone-clock PC 
override
2305(k)
0
Clock Health Inquiry 
Test (#46)
MAJOR
ON
set tone-clock PC 
override
2561(l)
Any
None
MAJOR
ON
3329(m)
0
None
MINOR/ 
WARNING
2
OFF
set tone-clock PC
3840(n)
Any
None
3848(o)
0
Clock Health Inquiry 
Test (#46)
set tone-clock PC 
override
3872(p)
0
None
set tone-clock PC 
override
3999 (q)
Any
None