Maintenance Object Repair Procedures 
Page 10-1498
TONE-BD (Tone-Clock Circuit Pack) 
10
For a system with a TN768, TN780 or TN2182 Tone-Clock Circuit Pack
:
Notes:
a. Refer to XXX-BD for descriptions of these tests.
b. Refer to TONE-PT for descriptions of these tests.
c. Refer to TDM-CLK for descriptions of these tests.
d. This test runs only on the standby Tone-Clock circuit pack in a Port 
Network with duplicated Tone-Clocks (High or Critical Reliability systems). 
The circuit pack must be a TN780 with firmware version 2 or above or a 
TN2182.
Clock Health Inquiry Test (#46)
This inquiry reads special data stored in memory to determine if this Tone-Clock 
circuit pack had a loss of any of three clock types:
SYSCLK
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long 
Test 
Sequence
D/ND
1
SAKI Reset Test (#53) (a)
X
Clock Health Inquiry Test (#46)
X
X
Control Channel Loop Around Test 
(#52) (a)
X
X
Tone Generator Crosstalk Test (#90) (b)
X
Tone Generator Transmission Test 
(#40) (b)
X
X
Tone Generator Audit/Update (#41) (b)
X
X
TDM Bus Clock Circuit Status Inquiry 
Test (#148) (c)
X
X
TDM Bus Clock Slip Inquiry (#149) (c) 
(e)
X
X
TDM Bus Clock PPM Inquiry Test 
(#150) (c)
X
X
TDM Bus Clock Parameter Update Test 
(#151) (c)
X
X
Board Type Check Test (#574) (c)
X
X
Standby Reference Health Check Test 
(#651) (c,d)
X