TONE-PT (Tone Generator) 
10
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the following tables when 
inspecting errors in the system. By clearing error codes associated with the 
SAKI 
Sanity Test
, for example, you may also clear errors generated from other tests in 
the testing sequence.
Use the 
list configuration control
 command to find the Tone-Clock Circuit Pack 
Code of the system. Then look for the Short and Long Test Sequences according 
to the Tone-Clock Circuit Pack Code.
For a system with a TN756 Tone-Clock Circuit Pack
Notes:
a. Refer to XXX-BD (Common Port Circuit Pack) Maintenance documentation 
for descriptions of these tests.
b. Refer to TONE-BD (Tone-Clock Circuit Pack) Maintenance documentation 
for descriptions of these tests.
c. Refer to Dual Tone Multifrequency Receiver Port (TTR) (DTMR-PT) or 
General Purpose Tone Detector (CPTR) (GPTD-PT) Maintenance 
documentation for descriptions of this test.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long 
Test 
Sequence
D/ND
1
SAKI Sanity Test (#53) (a)
X
D
Clock Health Inquiry Test (#46) (b)
X
X
ND
Control Channel Loop Around Test (#52) (a)
X
X
ND
Tone Detection Verification Test (#42) (c)
X
X
ND
Tone Detector Audit/Update Test (#43) (c)
X
X
ND
Tone Generator Crosstalk Test (#90)
X
ND
Tone Generator Transmission Test (#40) 
X
X
ND
Tone Generator Audit/Update Test (#41)
X
X
ND